 PETROLEUM CONTAMINATED SOIL PRE-BURN REQUIREMENTS

 1. Required Tests and Maximum Limits - F.D.E.P. 62-713

 Parameter/Property                                          Maximum Limit/Conditions

 TOTAL Arsenic(As)                                           .5 ppm Det limit

TOTAL Cadmium(Cd)
TOTAL Chromium(Cr)
TOTAL Lead(Pb)
TRPH (Method Fla Pro)
VOH  (Method 8021)
TOX                                                                  1000 ppm  (SEE NOTE 2)
PCB                                                                 50 ppm   (SEE NOTE 2)
    Det limit for PCB analysis is  20 ppb

2. Number of Samples for above tests:

Less than 140 Tons                                          1

140 to 699 Tons                                               3

700 to 1399 Tons                                             5

Ea Additional 700 Tons                                    1

3. Other General Requirements:

a.         Letter from Generator or Generator's Authorized Agent certifying that:

i)          Soil is NOT Hazardous Waste or Mixed with Hazardous Waste

ii)         Type of Contamination (Gas, Diesel, etc)

iii)         Source of Contamination (UST, spill, etc)

b.         Each load MUST be accompanied by a Shipping Manifest

4.         Notes:

(1)        Higher metal levels may be acceptable, subject to results of TCLP analysis.

(2)        TOX and PCB analyses are required for all used oils, including used hydraulic and mineral oils.

(3)        Final acceptance of soil is subject to approval at time of delivery.